Fill Valve Installation Instruction - Part 2/3

Fill Valve Installation
Fill Valve Installation 2/3


9. With correct WASHERS in place (see Step 8), tighten COUPLING NUT. Hand-tighten only. DO NOT OVERTIGHTEN. CAUTION: DO NOT USE CONE WASHER WITH PLASTIC SUPPLY LINE.

10. Clean drain with a soft cloth. Snap ADAPTER RING away from FLAPPER. Align FLAPPER over mounting ears located on base of OVERFLOW PIPE. Center FLAPPER over drain opening. Snap to mounting ears by pushing down on the rigid frame near mounting ears. FLAPPER should open and close without binding.

11. ADAPTER RING FOR 1" OVERFLOW PIPES WITHOUT MOUNTING EARS. If there are no mounting ears on base of OVERFLOW PIPE, install ADAPTER RING: 1) Position ADAPTER over top of OVERFLOW PIPE and press down until it expands and slips over the outside of the OVERFLOW PIPE. If the ADAPTER will not slide down OVERFLOW PIPE, remove spring, slip ADAPTER around the PIPE and replace spring; 2) Slide ADAPTER down until it contacts base of OVERFLOW PIPE. Position spring clip opposite the drain seat. NOTE: If OVERFLOW PIPE is brass, use steel wool or wet/dry sandpaper to remove excess scale from PIPE prior to installation. If OVERFLOW PIPE is larger than 1", Model 555C can be used.

12. If you have a Fluidmaster bowl cleaning system, re-attach tube (“IN”) to FILL VALVE NIPPLE (see Diagram 1). Be sure toilet tank flushing components move freely (if you don’t have a cleaning system, continue to Step 13).

13. Remove and discard overflow pipe cap if present. Attach one end of black REFILL TUBE to ANGLE ADAPTER and the other end to NIPPLE located near top of VALVE. Attach ANGLE ADAPTER to OVERFLOW PIPE. Trim REFILL TUBE as necessary to prevent kinking. NOTE: Flow from REFILL TUBE must be positioned just above the OVERFLOW PIPE. Do not insert REFILL TUBE down into OVERFLOW PIPE below water level. This will siphon water down the OVERFLOW PIPE, which causes the VALVE to turn on and off as it tries to keep the tank full. Hot Water Heaters If the ANGLE ADAPTER cannot be used, you may need the Model 599 Refill Clamp (not included).

Monday, June 27, 2011

Fill Valve Installation Instruction - Part 1/3

Fill Valve Installation
Fill Valve Installation - Part 1



1. Shut off water supply to tank. Flush tank and sponge out remaining water.
Remove old fill valve assembly, tank ball, and wire guide unit (or flapper), using
pliers if necessary.

2. If you have a Fluidmaster bowl cleaning system, carefully disconnect the
tube from the FILL VALVE. Do not disconnect the tube from the dispenser
(if you don’t have a cleaning system, continue to Step 3).

3. Disassemble small parts – LOCK NUT, SHANK WASHER and ANGLE
ADAPTER for VALVE installation (required); CONE WASHER and COUPLING
NUT for water supply connection (optional–see Step 8).

4. Carefully remove CONE WASHER from center of SHANK WASHER. Place
SHANK WASHER on THREADED SHANK of new VALVE. Place flat surface
against VALVE.

5. When installed, the CRITICAL LEVEL MARK on the FILL VALVE(identified
by a C.L. mark on the Fluidmaster FILL VALVE) should be at least 1"
above the top of the OVERFLOW PIPE. This is a plumbing code.

6. To adjust the height of the FILL VALVE, twist the THREADED SHANK in or out
of VALVE body. The height of the VALVE adjusts from 9 to 14 inches. On some
models, a clicking noise will be heard when adjusting the height. This is
normal.

7. Position VALVE inside tank. Push down on the VALVE SHANK (not the TOP)
while tightening LOCK NUT. Hand-tighten only. DO NOT OVERTIGHTEN or
tank may crack. Make sure FLOAT CUP does not touch toilet tank walls, trip
mechanism or FLUSH VALVE.

8. Before continuing, determine the type of water supply connection you have
from the chart on the left and use the appropriate assembly parts required to
properly reconnect the water supply. DO NOT use plumber’s putty to seal
these fittings.

Wednesday, June 8, 2011

Pro Alliance - Exclusive For The Plumbing Professional


Fluidmaster leads the way with innovation. Beginning with the development of the 400A, Fluidmaster has become the choice of plumbing professionals everywhere. This tradition of quality and innovation continues today as Fluidmaster creates the best, most efficient toilet repair products on the market. And now through their latest innovation you can be a part of the Fluidmaster team.